Testo® 523 To PDA Communications Loop Modification

June 29, 2008 · 2 Comments

We are interested in talking to anyone that has either successfully modified the IR communications loop betweeen the Testo® 523 and it’s printer to include a Palm or other PDA device, or anyone that is currently attempting to make this modification.

You can either respond directly to this post or contact us via email at digital.zeus@yahoo.com - you do not have to disclose your identity if you elect not to.

I know there is at least one technician that successfully made this modification, unfortunately I have lost contact with him as a result of a system crash, so it can be accomplished. Thanks for any input relevant to this topic. 

Categories: Applications · Digital Manifold Gauges · Guides · HVAC PROTech Forum · HVAC PROTech Technical Archives · Infrared · Modifications:Unauthorized · Schematics · Sensor Technologies · Technique · Technology · Tutorials

ANNIE® User’s Manual | Part’s List | Internal Schematics

May 18, 2008 · No Comments

ANNIE A-12 Full Manual: http://www.mediafire.com/?bjuyem4y9fz

ANNIE A-12X Full Versions of Screenshots in this Thread:  http://www.mediafire.com/?2gyyts2xlme 

The files above are in the Winzip and Winrar formats (respectively) that require you to decompress the folders after you have them downloaded on your system. Most operating systems are included with a compression/decompression (codec) that will decompress these files. If you do not refer to our HVAC PROTech® Technical Archives   HVAC FAQ’s Page and click the Utilities header, scroll down to Compression/Decompression Utilities. HVAC FAQ’s are located here: http://hvacprotech.org/faq%27s.html 

Categories: Diagnostics & Analysis · General Tools · Guides · HVAC PROTech Forum · HVAC PROTech Technical Archives · Meggers · Schematics · Troubleshooting

“ANNIE” Rebuild Schematics

December 30, 2007 · No Comments

Internal Schematics for an ANNIE Rebuild

SCHEMATIC PARTS LIST 

R1 – 8110 – 100K Resistor
R2 – 8110 – 100K Resistor
R3 – 8110 – 100K Resistor
R4 – 8220 – 12K Resistor
R5 – 8220 – 12K Resistor
R6 – 8235 – 8.2K Resistor
R7 – 8506 – Ohms Control
R8 – 8570 – Volts Control
D1 – 4502 - Diode
N1 – 4401 – Red Neon Light
N2 – 4402 – Clear Neon Light
N3 – 4403 – Amber Neon Light
M1 – 1003 - Ohmmeter
M2 – 1031 - Ampmeter
M3 – 1032 - Voltmeter
T1 – 4320 – Transformer Relay
T2 – 4330 – Transformer Current
B1 – 2315 – Battery 1.5 V Size D
F1 – 4220 – Fuse 20 amp
S1 – 7205 – Ampmeter Switch
S2 - 7210 – Voltmeter Switch
S3 – 7305 – Master Switch
S4 - 7310 – Ohmmeter Switch
S5 – 7315 – Capacitor Switch
S6 – 7601 – Start Switch
C1 – 2205 – Capacitor 47 mFd
C2 – 2208 – Capacitor 108 mFd
S1 & S2 Are Maintained DPDT Toggle Switch with Centre Off
S3 Is a Maintained DPDT Toggle Switch With Centre Off. Position A is Start Forward, Position B is Start Reverse
½S4 is A Maintained Toggle switch with centre OFF
½S4 is A Maintained Toggle Switch with centre ON
S5 is A Maintained Toggle Switch – Position A, C1 Is engaged, Position B, C2 Is Engaged, Centre Position C1 & C2 Are Both Engaged.
S6 is a Momentary SPST N.O. Push Button Switch

The Schematic

 annie9eq1.png 

Click for full sized image. For fuller detail visit the thread below.

For complete operating Guidelines reference this Article: http://hvacprotech.forumwise.com/hvacprotech-thread300.html

Categories: Analog · Applications · Diagnostics & Analysis · Guides · Schematics