Digital Zeus™ HVAC Tool & Instruments Journal

Entries categorized as ‘Data Logging’

Testo® RSA 523 | 556 | 560: The Differences

May 22, 2008 · No Comments

We get alot of emails from tech’s asking the differences in the Testo First and Second Generation 523’s, the 556 and the 560’s. This article will be a very basic summary of those differences. Keep in mind the Testo 500 Series RSA’s are complex, advanced refrigeration system diagnostic instruments - in particular the 556 and the 560. Each can be fully customized and configured to suit literally every field application. We strongly recommend that prior to making an investment in any of these three instruments that you contact TRUTech Tools at http://www.trutechtools.com They will discuss with you in detail the capabilities, available configurations and make a customized package recommendation designed for each technician’s specific requirements. We also, obviously recommend registering at HVACPROTech.com and accessing the most complete, unbiased data based on FieldTests and member evaluations of these instruments available anywhere on the internet.

Testo 523: Generation 1

The First Generation 523 is no longer in production and is not available directly from Testo. It is still available, in limited quantities from TRUTech. If you are considering the transition from analog to digital manifold gauge technology this is definitely an option that merits consideration. The First Generation 523 was originally marketed under the trade name Testo Kool and depending upon where and when you purchased it listed for anywhere from $700.00 up to $1050.00. This version was an exceptionally advanced instrument, particularly in consideration of it’s release date and in comparison to the alternative standard at the time, the analog manifold gauge. From a strictly physical appearance perspective, as you can see below - the First and Second Generations hold little resemblance to one another.

523 Side x Side

The Second Generation 523 display screen is significantly larger. The valve handles recess, the vertical structure of the case has been refined to include slightly concaved recesses on either side for easier handling. The Second Generation is a sleeker, refined, modern and by the description of some who have evaluated it a ”sexier” looking design :P

Tempting Testo

When you look past the appearances there are differences in the 1rst and 2nd Generations that merit mentioning. The 1rst Gen. 523 was equipped with the capability to data log - a capability and a function that has widely beed used as a diagnostics tool in commercial applications for many, many years, and one whose effectiveness and versatility is very quickly being discovered by the technician community. This capability was ”designed out” of the 2nd Gen. 523 - it it’s place the option of communicating the systems operational parameters via infrared signaling to a thermal printer was designed in. The 2nd Generation 523 can be purchased with the infrared printer included with the instrument or without it. A sidenote that I find an admirable quality in Testo is the fact that their IR platform accomodates all IR compatible instruments in their line, so in this case one size really does fit all. Additional less than obvious differences are the change in sensors. The 1rst Gen utilized an absolute pressure [ http://en.wikipedia.org/wiki/Absolute_pressure ] sensor, whereas the 2nd Gen utilizes a relative pressure [ http://en.wikipedia.org/wiki/Relative_pressure ] sensor. A “nulling” [ refer to this article: http://digitalzeus.wordpress.com/2008/01/09/digital-gauge-dictionary-zeroed-or-nulled/ to learn more about the relevance of nulling ], value was also designed in to the instrument. The final note relevant to the 1rst Gen 523 is applicable to all digital manifold gauges, but specifically those that are housed or left seated in a poly case, such as those the 500 Series RSA line is packaged in. When charging liquid into a system, with the manifold gauge seated in it’s case an inherent risk of damage as a result of static discharge [see the demonstration below] is present.

The entire Second Generation 500 Series RSA’s have enhanced protection in comparison to their First Generation counterparts against static discharge damage. [It is still our recommendation, even given the enhanced protection that the RSA be removed from it's case and hung from the equipment to establish a ground path when charging liquid into the equipment]. The last remaining available original, in the box ”Testo Kool” 523’s that I am personally aware of are available from TRUTech. TRUTech offers the option of either purchasing the base 523 [without data logging support peripherals ie., software and cable] for approximately $350.00 - it is also available with data logging support peripherals for approximately $425.00. A PROTech highly recommended value.

Testo 523: Generation 2

If you’ve spent 10 minutes around computers, then you’ll know when you see the familiar little v. that it is representative of a version change - that can be interpreted in one of two ways, depending I suppose on whether you are an optimist or a pessimist. It can mean either new and improved or broken and fixed. Both of those analogies can be applied to the Second Generation 523. Originally introduced as the RSA 523 v. 2.00 - the instrument was recalled due to a potential issue relevant to manifold integrity and the concern that refrigerant loss was a possibility, the resulting correction was the addition of a hose port protective skirt, [see the side by side illustration below]:

Aside from the above noted revision there are no physically distinguishable differences in v. 2.00 and v. 2.01of the 2nd Gen 523. [This revision was actually academic, and was obviously made at no cost to the technician - the only reason it merits mentioning is to caution the technician that may consider purchasing this instrument from a source that is not recognized as an authorized source, as an example, from a private seller on EBay. If you see this instrument without it's protective skirting, there is the possibility of known refrigerant loss at the manifold ports]. The second and as of the date of publish of this article, the final revision made to the 2nd Gen. 523 was a firmware flash. This revision also requires the instrument be returned to Testo New Jersey for implementation. Even though the 523 is primarily marketed as a residential applications instrument [an inaccurate characterization, in my experience], FieldTesting of the 523 revealed that it’s refresh or update rate was not adequate in setting or varifying intricate pressure controls like those typically found in commercial and transport refrigeration equipment, [a side by side illustration of the refresh rate prior to flashing and following flashing is below]:

This revision, by means of a firmware flash resulted in the designation of the RSA 523 v. 2.02. The following data relevant to the features and capabilities of the 2nd Generation 523 v. 2.02, in the quoted areas are extracted from the TRUTech Tools website, remember TRUTech builds and esigns custom RSA packages. Specific accessories included with TRUTech custom packages are not reflective of all autorized distributors of these instruments. TRUTech typically excels in both value and support and service, if you do not intend to purchase this instrument from them consult the vendor of your selection.

Unparalled Features:

1. Ability to print the measurement results on site via wireless printer

2. High stability ceramic relative pressure transducers

3. Large backlit display, and intuitive user operation

4. Three and four valve designs are available with a 3/8-evacuation port on four valve manifolds

5. High durability valve handles with Teflon seats

6. Backlit sight glass and display

7. Hose holder with integrated LCD protection

8. Pre loaded refrigerants: 30

No other product made can compete at any level. Testo has taken a quantum leap forward in AC/R measurements allowing the lab technician or service technician to deliver consistently accurate results to owners, manufacturers and end users of air conditioning and refrigeration equipment

Superheat and Subcooling Measurement: Thirty on board temperature pressure charts provide unparalleled detail and accuracy of refrigerant saturation temperatures, superheat and subcooling. Unlike traditional paper charts no interpolation of the temperature-pressure relationship is required. It is now possible to measure and set superheat and subcooling with laboratory accuracy in the field as the Testo 523 reads pressures and temperatures to the tenth of a psi and tenth of a degree and automatically calculates real-time superheat and subcooling values. Temperature measurement is just as critical as pressure when commissioning and servicing equipment.

Temperature: The platinum based (platinum film on a ceramic substrate) 4-wire construction, of the spring loaded temperature sensor (Pt-100) has a very low mass (yielding a fast response) and is not affected by stray voltages that may be present on the refrigeration equipment. Unlike traditional K-type thermocouples, the sensor is electrically isolated from the RSA. Isolating the temperature sensor electrically form the system eliminates the possibility of incorrect temperature measurement resulting from stray electrical currents or ghost voltages often present on improperly grounded refrigeration and air conditioning systems. Because the resistance of a Pt100 sensor bears an absolute relationship to temperature (unlike a thermocouple whose output depends on the difference between the hot junction and cold junction) no special compensating circuit needs to be provided in the electronics. In short, the Pt100 has a wide operating range, excellent accuracy, good linearity, excellent physical strength, long-term stability, and is the preferred sensor for all industrial processes where accuracy and repeatability are required. Additionally, Pt100 probes may be replaced without recalibration of the RSA instruments. Sensors are available in lengths up to 40 feet. The Velcro-elastic strap provides insulation from ambient air along with positive contact to the refrigeration line from ¼” to 3” in diameter. Air and immersion probes are available to further enhance your testing applications.

Time: Incorporated into the system analyzer is a new dimension; time. The entire new generation of RSA products incorporates a real time clock that permits accurate documentation of the time and date readings were recorded via the wireless printer or data logging. Testo was first-to-market with a complete line of refrigeration system analyzers that incorporate data logging, and now the first to bring wireless printing to the complete line. Owners of Testo combustion or other test equipment that already use a wireless printer will benefit from cost savings, as the printer is universal to all Testo products. A printout of the final operating parameters on all RSA products allows for field documentation of operating at system startup or pre and post operation.

The Testo 523digital refrigeration/air conditioning system analyzers are a multipurpose tool designed for every day use replacing a gauge manifold, superheat or subcooling thermometers, pressure-temperature charts, etc.. with a rugged hand held versatile tool.

Included in the kit:

  • 523 RSA & Pipe Clamp Probe
  • Hose Keeper/ Screen Protector Accessory  
  • Note that while the package above is infrared ready, it is not equipped with the infrared thermal printer. This is an available option or the printer can be purchased ata later date.

    Testo 556/560 : Generation 2 

    Seem like too much information yet? :) The 523 was the easy part. The instrument capabilities as well as complexities drastically increase with the 556/560 models. Selection of either of these two instruments is where the importance of configuration packages become critical, and as we have several times prior, strongly recommend you contact TRUTech Tools for guidance and recommendations relevant to your specific applications and the peripherals you will want to include with your individual configuration package.

    The 556 and the 560 repectively, are referred to as a professional and planned service instrument and a professional, planned service and commissioning instrument. So what seperates the 556 from the 523 - the 556 incorporates a 4 valve manifold [below with a 3/8" service port], configuration (with illuminated sight glass), whereas the 523 manifold configuration is 2 valve.

     

    The 556 also facilitates the potential to connect a total of 4 temperature probes. Wireless temperature measurements can be acquired from a distance of 65.616′ unobstructed.

    When used in tandem with optional EasyKool software a total of 60,000 readings can be stored and referenced. An exceptionally wide variety of accessories are available to complement the 556 for virtually any known application. A list of these accessories is provided below. One of the reasons, assuming you’ve noticed, that the 556 and the 560 are often referenced in unison (556/560} is due to the fact that a single capability seperates the two. The 560 is available with a high quality pressure sensor to facilitate acquisition of absolute pressure and the display of corresponding  evaporation temperature of water.

    The 556/560 are each divided into two seperately designated appendices to their base model designations that should be noted. Base instrument model designations may be followed by either a 1 or a 2, (556-1 | 556-2), (560-1 | 560-2) - in both instances these appendices designate the refrigerant application suitability. [1] indicates a brass instrument that is suitable for at least the 30 refrigerant profiles [profiles listed below] included with the RSA Series, excluding NH3. The designation of numeral [2] indicates a stainless steel version designed for use in NH3 applications.

     The data in the thumbnails below are specification sheets and available Accessory options. Click on the thumbnails for a full sized view of each document.

    Testo RSA 523 | 556 | 560 Specification Sheet

    Testo RSA 523 | 556 | 560 Accessory Profiles

    Please remember this is a very limited, brief overview of the differences seperating Generational changes and model features and capabilities. This article should not be used to determine the configuration you will need for your individual applications. I very strongly recommend, if you are considering the purchase of either the 556/560, that you give TRUTech Tools a call and discuss your applications requirements and your own personal preferences relevant the what you want to be able to do with the instrument and what you may not want. Talk to Jim, tell him Zeus sent you. Contact information is available at http://www.trutechtools.com and remember for real world field experiences and capabilities of these and other instruments - http://www.hvacprotech.com

    Categories: Applications · Commentary · Data Logging · Diagnostics & Analysis · Digital · Digital Manifold Gauges · Evacuation · FieldTest Evaluations · Guides · HVAC PROTech Forum · HVAC PROTech Technical Archives · Infrared · Pressure · Refrigerants/Refrigerant Properties · Sensor Technologies · Subcooling · Superheat · TRUTech Tools · Technology · Temperature · Thermocouples · Transducers · Troubleshooting · Tutorials

    Testo® 556 RSA: First Impressions

    May 15, 2008 · No Comments

    Testo® 556: First Impressions

    I’m new to the boards here and I’m not sure if this is the section I should post this in, so if I’m mistaken, please correct me.
    I received the 556-1 wireless kit the recently and today was the first chance that I got to use it. The first machine it saw was a 3 ton coolair split that is having occaisional low pressure lock out problems. I’m the third tech on this call and I have not seen the machine until today so I figure this will be a good opportunity to see what this DRSA is all about.

    Right off the bat it’s plain to see that this instrument, yes instrument is not for every job. It is rather bulky ( when in case ) and I can’t see techs climbing up and down ladders and running around mechanical rooms with it on a daily basis. I don’t know about you but I like to travel light and usually only carry a small tool bag. I’ll go back to the truck if I think I need gauges. All of my work is commercial and more often then not the problem is electrical in nature. Besides I think that most of us here can tell if a unit is running okay just by feel alone.

    With that in mind I have to say that this is the first set of digital gauges that I have ever used and you know what ? I like them. On the call I was on today first tech says TXV is bad, second tech says unit is under charged and has dirty condenser coil. I check and find 125 foot pipe run, 2 liquid line driers ( one at c/u and one inside a/h ), poor airflow evap and excessive pressure drop at a/h. what the 556 allowed me to do was measure pressures,superheat and sub cooling at both locations record them and download them to my laptop all on site. Gauging up was easy and most important of all, quick. The ability to record and transfer the data gathered is not to be underestimated.

    The 556 seems rugged enough for its intended use and was relatively easy to set up initially. The display is clear and easy to read and the backlight worked very well. What a pleasure it was to actually see superheat and subcool values along with pressure without having to stop and consult pt chart and then do calculation. I can see that the accuracy of this instrument is a vast improvement over analog gauges. I can tell you that I checked system with my Y/J manifold and when I disconnected them the low side gauge needle was stuck at 15 psi. They were less then a month old and weren’t dropped that I know of. If I wasn’t convinced before I am now.  

    Read More of This Evaluation at HVACPROTech.com®

    The Only Professional Technicians Boards with Comparative Instrument Analysis

    Everyone - This is exactly what i’m trying to get at. It is s fact of life in most companys that you can’t always get the same tech back to the same call. The variability of readings across different gauges and techs is what I would like to see minimized. I Know that for a purely empirical test of analogs vs digital ( excuse me DRSA’s ) I would absolutely agree that duplicating sensor locations and hose connection locations is rule # 1.

    The very reason that i even purchased the 556 was so that i could develop some level of confidence in the readings taken by multiple techs across all types of equipment in sometimes less than optimal conditions. Some techs have $400 multi sensor temp kits, some are using fieldpiece, one kid even showed me where he tucked the tip of his pocket digital thermometer under the suction piping insulation. Add to that the inaccuracy inherent in analogs and we can all see that is time for a change.

    Field Applications

    Hello everyone – today was the third time i have used the 556. today’s patient was a 80 ton Trane water cooled VAV unit with four compressors, each with single circuit. Age of unit is appx 20 years old. Several of these units have developed leaks and I havn’t found them all yet. I’ve used electronic leak detectors, Halide torches, bubbles and dye. As this is typical of the type of service work most of us encounter I thought it would be a good trial for the 556.

    The 556 is rugged and appears well suited to field use. It is very easy and intuitive to use and dare I say fun. What a pleasure it is to watch s/h & s/c readings in real time. Here is a picture of the setup I used before the TESTO arrived.

     I underestimated the time saved and ease of gauging up to equipment.. I attached wired probe to LL line and wireless probe to suction line. I left radio handle inside unit and it broadcasted temp signal to 556 flawlessly. Yesterday I could not get it to read s/h & s/c values. Then I realized that I forgot to enter refrigerant type. After that okay. Here is a picture of both the old way and the new way of checking charge. I like the new way better.

    The only place to find hard field data on the diagnostics instruments you use. HVAC PROTech.com® http://www.hvacprotech.com

     

    Categories: Applications · Data Logging · Diagnostics & Analysis · Digital · Digital Manifold Gauges · FieldTest Evaluations · Guides · HVAC PROTech Forum · HVAC PROTech Technical Archives · Sensor Technologies · Technique · Technology · Uncategorized

    Testo® 435 Comparative Capacity Verification with the Testo® 556

    May 6, 2008 · No Comments

    More colors listed than colors at the bottom. Was running 2 temp humidity wirless probes will try and send the pdf on all the temp’s. It’s a Luxaire 2.5 ton heat pump with expansion valve. 10 degrees of subcooling. Just started working with these charts will try and get the other out. Humidity inside and outside with indoor and outdoor temps.

    Your only source for field tested evaluations of the advanced diagnostics instruments the professional technician uses, http://www.hvacprotech.com 

    Categories: Air Properties · AirFlow · Commentary · Data Logging · Diagnostics & Analysis · Digital Manifold Gauges · FieldTest Evaluations · Guides · HVAC PROTech Forum · HVAC PROTech Technical Archives

    Manifold Gauges: [ΦThe Definitive Guide]: Excerpt

    January 15, 2008 · No Comments

    Below is a brief excerpt from the Digital Section of the exclusive HVAC PROTech.com®  publication Manifold Gauges: [ΦThe Definitive Guide] available Spring of 2008. The most comprehensive online Guide dedicated completely to the manifold gauge digital and analog, manifold body configurations, hose selection options and benefits, the Bourdon Tube, the diaphragm, transducers. It’s all here. Reserve you Adobe® PDF formatted copy today.

    Additional differences in design fundamentals between generations 1 and 2 [Generation 2 pictured below.] are relatively obvious by simple appearance alone. The display screen has been significantly improved, note that the handles have been offset slightly in the second generation version.


                   Second Generation Testo 523 RSA.

    The handles also retract to provide additional protection when not in use. Both the sightglass as well as the display screen offer backlighting capability. The 523 pictured above was also originally released without a hose holder for the dead end of the hoses, an accessory was later offered that combined blanks for hose parks and a screen protector - this option however, has met with relatively little acceptance by the technican community as a whole. Our own Fieldtests of the 523 revealed that the composition of the accessory was not well suited to lower temperatures [it becomes very brittle] encountered by users in northern climates. Note that the illustration above of the second generation 523 was as it appeared in it’s initial release, prior to the recall exercised by Testo. The revised version of the second generation 523 [illustrated below] included the circled tailpiece, added for protection of the pressure/vacuum inlets.


    Second Generation: Version 2 of the 523 RSA. Note the added protection [circled] to the transducer inputs as it compares to the initial release of the second generation 523

    The addition of the transducer input protection tailpiece to the revised second generation release of the 523 may hold some significance to the technician that makes a practice of purchasing instruments from online auction sites or distributors such as Ebay. If you see the 523 v.1 without this added protection the instrument has not been returned for the factory recall correction. The recall dealt with a potential compromise in the integrity of the manifold that may have resulted in refrigerant loss. I am not clear of whether any actual occurrences of this potential issue were documented or not, so caveat emptor if a purchase is made without the tailpiece in place on this particular instrument.

    Categories: Analog · Applications · Data Logging · Diagnostics & Analysis · Digital Manifold Gauges · Evacuation · FieldTest Evaluations · Guides · HVAC PROTech Forum · HVAC PROTech Technical Archives · Sensor Technologies · Technology · Transducers · Troubleshooting